Transformer protection device
RET670 1MRK002816-AB Transformer protection device
RET670 1MRK002816-AB Transformer protection device
The RET670 provides selective and rapid protection, monitoring and control for two – and three-coil transformers, autotransformers, phase-shift transformers, transformer banks, special railway supply transformers and shunt reactors. The RET670 can operate correctly over a wide frequency range and can adapt to system disturbances or system frequency changes during generator start-stop.
RET670 1MRK002816-AB Transformer protection device
REF545KB133AAAA FEEDER TERMINAL protection device
The RET670 is extremely sensitive to minor internal faults in the transformer. The RET670’s unique and innovative sensitive differential protection based on the symmetric component method maximizes the internal interturn short-circuit fault of the winding. Zero-sequence current differential protection of the low impedance type can be used as a complement to the fast and sensitive main protection response to ground faults. The additional zero sequence current direction criterion further improves the safety.
peculiarity
• Fully compliant with IEC 61850 standards
• Integration of monitoring and protection functions
• Comprehensive self-test capabilities, including analog channel self-test
• Six independent parameter setting groups
• Switch and analog signal matrix, easy to set
• Ethernet interface for quick and easy communication with PC
• Large screen man-machine interface, you can browse the connection between each interval and the bus and the status of the primary device online
• Pre-configured solutions with default tuning through type testing can be used to:
– Single bus connection, 1 1/2 circuit breaker connection, double bus connection
– Double bus and single circuit breaker
• User management and permission Settings
Main protection function
• Two bus differential protection action areas
– Sensitive differential protection action characteristics
– Automatic monitoring of current loop break and selective blocking of corresponding busbar protection
– Super fast action
– High stability against out-of-area faults
– Correctly reflect various types of conversion and developmental failures
• Large differential protection features
• Built-in software to automatically select the bus measurement area (corresponding to the isolation switch position)
• Circuit breaker failure protection
• Selective trip outlet for busbar protection and circuit breaker failure protection
• Four sections of directional overcurrent protection with fixed or inverse time characteristics
• Automatic reclosing function for delayed recovery after busbar protection action
• Programmable logic function module
• Support external auxiliary CT and current input