TRICONEX 4211 Power Modules
TRICONEX 4211 Power Modules
The Triconex Tricon Safety Instrumented System is designed to meet the needs of safety and critical control applications in oil and gas, power, refining, chemicals, pharmaceutical and biotech industries.
It is based on industry leading TMR technology, is easy to operate and maintain and provides the lowest total cost of ownership.
Models 3502E, 3503E, and 3505E can self-test to detect stuck-On conditions where the circuitry cannot tell whether a point has gone to the Off state. Since most safety systems are set up with a deenergize-to-trip capability, the ability to detect Off points is an important feature. To test for stuck-On inputs, a switch within the input circuitry is closed to allow a zero input (Off) to be read by the optical isolation circuitry. The last data reading is frozen in the I/O communication processor while the test is running.
Main Processor Modules:
3008 Main Processor, 16 megabytes DRAM Triconex3008
Communication Hardware and Software:
Tricon Communication Module (TCM), Ethernet (802.3) and serial (RS-232/RS-485) ports
4351A, Triconex4352A,
4351B, Triconex4352B
4353, Triconex4354
Enhanced Intelligent Communication Module (EICM), serial (RS-232/RS-422/RS-485) ports Triconex4119, Triconex4119A
Safety Manager Module (SMM), Honeywell UCN Interface Triconex4409
Network Communication Module (NCM), Ethernet (802.3) ports Triconex4329, Triconex4329G
Main Chassis—houses Main Processors, memory back-up batteries, communication modules and I/O modules.
Expansion Chassis—for additional I/O modules up to 100 feet (30 meters) away from the Main Chassis. In restricted applications, operation up to 1,000 feet (300 meters) is supported.
RXM Chassis—for I/O modules up to 7.5 miles (12 kilometers) away from the Main Chassis.
APPLICATIONS:
Emergency Shutdown (ESD)
Burner Management Systems (BMS)
Fire and Gas Systems (F&G)
High Integrity Pressure Protection systems (HIPPS)
Turbomachinery Controls (TMC)
Critical Control
Chassis Assemblies:
Main Chassis, High-Density Configuration, includes the Tricon printed manuals Triconex8110
Expansion Chassis, High-Density Configuration Triconex8111
Expansion Chassis, Enhanced Low-Density Configuration Triconex8121
Remote Expansion Chassis, High-Density Configuration Triconex8112
I/O Bus Expansion Cables (Set of 3) Triconex9000
I/O-COMM Bus Expansion Cables (Set of 3) Triconex9001
Blank I/O Slot Panel Triconex8105
Model
Description
3501E/T 115Vac/Vdc Digital Input
3502E 48Vac/Vdc Digital Input
3503E 24Vac/Vdc Digital Input
3504E 24/48Vdc Digital Input
3505E 24Vdc Digital Input
3564 24Vdc Digital Input (simplex)
3511 Pulse Input
3515 Pulse Totalizer
3601E/T 115Vac Digital Output
3603B/E/T 120Vdc Digital Output
3604E 24Vdc Digital Output
3607E 48Vdc Digital Output
3611E 115Vac Digital Output
3617E 48Vdc Supervised Digital Output
3623E/T 120Vdc Digital Output
3624 24Vdc Supervised Digital Output
3625 24Vdc Digital Output
3664 24Vdc Digital Output (Dual)
3674 24Vdc Digital Output (Dual)
3636R/T Relay Output
3700A 0-5Vdc Analogue Input
3701 0-10Vdc Analogue Input
3703E 0-5, 0-10Vdc Analogue Input
3704E 0-5, 0-10Vdc (high density) Analogue Input
3706A Thermocouple Analogue Input
3708E Thermocouple Analogue Input
3720 0-5Vdc Analogue Input
3721 0 to 5 or –5 to +5Vdc Analogue Input
3805E/H 4-20mA Analogue Output
3806E 4-20mA and 20-320mA Analogue Output
3807
There are no reviews yet.