Vibro-meter VM600 RPS6U Power module
The VM600 RPS6U power module is specifically designed for the VIBRO-METER VM600 series mechanical protection systems and condition and performance monitoring systems. It can provide power to the modules (cards) in the entire rack, ensuring the stable operation of the system.
Vibrometer VM600 RPS6U Power module Parameter table
Environmental requirement
temperature
1: Run 0 to 70 °C (32 to 158 °F)
2: Storage −40 to 85 °C (−40 to 185 °F)
Humidity: (according to IEC 60068-2-30) 5 to 95%, non-condensing
Vibration:(According to IEC 60068-2-6) 0 to 55 Hz, below resonance peak and 0.35 mm above 2 g peak, 6 hours/axis
Status light
IN green indicates that the external power supply is within the normal range.
+5V Yellow indicates that + 5 volts DC power is being generated and is within the normal range
+12V Yellow indicates that + 12 volts DC power is being generated and is within the normal range
−12V Yellow indicates that -12 volts DC power is being generated and is within the normal range
Connecting back Two large current connectors DIN 41612 H15 type. Share power voltage and signal via the VM600 frame backplane (ABE04X)
Weight (approx) : 2.4 kg (approx. 5.3 LBS.)
The following table shows the maximum allowable duration of external AC or DC power interruption (cut-off) as input voltage to the RPS6U frame. The maximum duration value depends on the combination of the maximum load supplied by the RPS6U frame and the number of power supplies and cards installed in the VM600 frame (the actual load of the VM600). If a longer interruption duration exceeds the maximum duration, the VM600 card resets.
Different versions of CPUx/IOCx rack controller and communications interface card pair are available, as follows:
1:The CPUM/IOCN is the original version with a front-panel display and support for Modbus RTU/TCP or PROFINET (PNR 200-595-VVV-VVV).
2:The CPUR/IOCR is a version with rack controller redundancy and support for Modbus RTU/TCP (PNR 600-007-VVV-VVV).
3:The CPUR2/IOCR2 is a version with mathematical processing of fieldbus data and support for Modbus TCP and PROFIBUS DP (PNR 600-026-000-VVV).
Vibro-meter VM600 product recommendations
200-510-076-114 200-510-111-034 VM600 MPC4丨Vibro-meter machinery protection card ,200-582-915-032 VM600,VM600-ABE040 204-040-100-011,620-002-000-113 620-003-111-112 VM600 XI016T,200-566-000-012 200-566-101-012 VM600 IOCN,200-560-000-018 200-560-101-015 VM600 IOC4T,620-002-000-113 620-003-111-112 VM600 XIO16T,VM600 RPS6U 200-582-200-011,VM600 RPS6U 200-582-500-013,VM600 CPUM 200-595-100-014,VM600 MPC4 200-510-071-113 200-510-111-034,VM600 CPUM ,VM600 MPC4 ,VM600 MPC1,200-510-017-019 200-510-111-013 VM600 MPC4,
There are no reviews yet.